6 OPTIONS AND PERIPHERAL EQUIPMENT
6.17 MR-J3-D05 safety logic unit
269
6
• Connecting wires with a screwdriver
If using a screwdriver when connecting wires, do not insert the screwdriver with too much force. Doing so may damage the
housing or spring. Be careful when working.
Applicable screwdrivers
Connecting wires
1.
Insert the screwdriver at a slight diagonal into the front slot, push the spring up as if prying it, and in that state, insert the
wire until it reaches the stop. Take care not to insert the screwdriver with too much force as this may damage the housing
or spring. Never insert a screwdriver into the round hole for wire. Doing so will damage the connector.
2.
Continue to press on the wire and pull out the screwdriver to complete the wire connection.
3.
Pull the wire lightly to confirm that the wire is surely connected.
4.
To remove the wire, as when connecting the wire, push the spring down with a screwdriver and pull the wire out.
■
Inserting the connector
Ensure the connector is straight, then insert it into the socket until you hear and feel it click into place. When removing the
connector, press down the locking part completely, then pull out the connector. If the connector is pulled out while the locking
part pressed down only partway, the lock may get caught and cause damage to the housing, contacts, or wires.
■
Applicable wires
The following table lists applicable wires that can be used.
Screwdriver shape
φ
2.3 mm
Screwdriver shape
φ
2.5 mm
Shaft diameter: 2.3 mm ± 0.05 mm
Length: 120 mm or less
Blade width: 2.3 mm
Blade thickness: 0.25 mm
Tip inclination: 18° ± 1°
Shaft diameter: 2.5 mm ± 0.05 mm
Length: 120 mm or less
Blade width: 2.5 mm
Blade thickness: 0.3 mm
Tip inclination: 12° ± 1°
Conductor area
mm
2
AWG
0.22
24
0.34
22
0.50
20
φ
2.3 mm ± 0.05 mm
0.25 mm
2.3 mm
18° ± 1°
0.3 mm
2.5 mm
φ
2.5 mm ± 0.05 mm
12° ± 1°
Tool insertion slot
Screw driver