238
6 OPTIONS AND PERIPHERAL EQUIPMENT
6.12 Power factor improving AC reactor
400 V class [G] [A]
*1 Use this for grounding.
*2 Maximum dimensions. The dimensions vary depending on the curvature of the input/output lines.
*1 Use this for grounding.
*2 Maximum dimensions. The dimensions vary depending on the curvature of the input/output lines.
Servo amplifier
Power factor
improving
AC reactor
Dimensions [mm]
Terminal
size
Mass [kg]
W
W1
H
D1
D2
d
MR-J5-60_4_
FR-HAL-H1.5K
135
120
115
59
59.6
45
M4
M3.5
1.5
MR-J5-100_4_
FR-HAL-H2.2K
135
120
115
59
59.6
45
M4
M3.5
1.5
MR-J5-200_4_
FR-HAL-H3.7K
135
120
115
69
70.6
57
M4
M3.5
2.5
Servo amplifier
Power factor
improving
AC reactor
Dimensions [mm]
Terminal
size
Mass [kg]
W
W1
H
D1
D2
d
MR-J5-350_4_
FR-HAL-H7.5K
160
145
142
91
91
75
M4
M4
5.0
W ± 0.5
W1
R X
Z
S Y T
H ± 5
D1
D2
Y
Z
S
T
MC
MCCB
FR-HAL-H
X
R
L1
L2
L3
4-d mounting hole
*1
(
φ
5 slot)
Servo amplifier
3-phase 400 V class
D or less
3-phase
380 V AC to
480 V AC
W ± 0.5
W1
D1
D2
H ± 5
125
150
Z
Y T
R X S
Y
Z
S
T
MC
MCCB
FR-HAL-H
X
R
L1
L2
L3
4-d mounting hole
*1
(
φ
6 slot)
Servo amplifier
3-phase 400 V class
D or less
3-phase
380 V AC to
480 V AC
Содержание MELSERVO-J5 MR-J5-G Series
Страница 1: ...MR J5 User s Manual Hardware MR J5 _G_ MR J5W_ _G_ MR J5 _A_ Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 473: ...12 USING A FULLY CLOSED LOOP SYSTEM 12 7 Absolute position detection system 471 12 MEMO ...
Страница 477: ......