Appendix 1. Program Error
574
Error No.
Details
Remedy
P381
No spec: Arc R/C
Corner chamfering II /corner rounding II was
specified in the arc interpolation block
although corner chamfering/corner rounding II
is unsupported.
• Check the specifications.
P382
No corner movement
The block next to corner chamfering/
corner rounding is not a movement command.
• Replace the block succeeding the corner
chamfering/corner rounding command by
G01 command.
P383
Corner movement short
In the corner chamfering/corner rounding
command‚ the movement distance was
shorter than the value in the corner
chamfering/corner rounding command.
• Make the corner chamfering/corner rounding
less than the movement distance since this
distance is shorter than the corner chamfering/
corner rounding.
P384
Corner next movement short
When the corner chamfering/corner rounding
command was input‚ the movement distance
in the following block was shorter than the
length of the corner chamfering/corner
rounding.
• Make the corner chamfering/corner rounding
less than the movement distance since this
distance in the following block is shorter than
the corner chamfering/corner rounding.
P385
Corner during G00/G33
A block with corner chamfering/corner
rounding was given during G00 or G33 modal.
• Recheck the program.
P390
No spec: Geometric
A geometric command was issued though
there are no geometric specifications.
• Check the specifications.
P391
No spec: Geometric arc
There are no geometric IB specifications.
• Check the specifications.
P392
Angle < 1 degree (GEOMT)
The angular difference between the geometric
line and line is 1° or less.
• Correct the geometric angle.
P393
Inc value in 2nd block (GEOMT)
The second geometric block was specified by
an incremental value.
• Specify this block by an absolute value.
P394
No linear move command (GEOMT)
The second geometric block contains no
linear command.
• Specify the G01 command.
P395
Illegal address (GEOMT)
The geometric format is invalid.
• Recheck the program.
P396
Plane selected in GEOMT ctrl
A plane switching command was executed
during geometric command processing.
• Execute the plane switching command before
geometric command processing.
P397
Arc error (GEOMT)
In geometric IB‚ the circular arc end point
does not contact or cross the next block start
point.
• Recheck the geometric circular arc command
and the preceding and following commands.
P398
No spec: Geometric1B
Although the geometric IB specifications are
not included‚ a geometric command is given.
• Check the specifications.