![Mitsubishi Electric M700V Series Скачать руководство пользователя страница 269](http://html.mh-extra.com/html/mitsubishi-electric/m700v-series/m700v-series_programming-manual_238523269.webp)
13. Program Support Functions
13.1 Fixed Cycles
257
(3) Relation between the parameter setting values and tap axis movement for a synchronous tap
in-position check
#1223 aux07
Bit3 Bit4
Bit5
Bit2
Synchronous
tapping
in-position
check
At hole
bottom
At
R point
At
I point
→
R point
Hole bottom
wait time
Operation
at hole bottom
Operation
at R point
Operation at
I point
→
R point
0 —
—
—
Time designated by "P".
Processing time is
several 10ms when no
"P".
Operation
determined by
setting of inpos
(#1193) and aux 07
(#1223): bit 1
parameters.
Operation
determined by
setting of inpos
(#1193) and
aux 07 (#1223):
bit 1
parameters.
Operation
determined by
setting of inpos
(#1193) and aux 07
(#1223): bit 1
parameters.
1 0
0
1
Larger value of "P" and
TapDwl (#1313) is valid.
No dwell executed if
both values are 0.
Wait until time in
left column has
elapsed.
Wait until completion
of in-position check
by G0inps value.
1 0
1
1
Larger value of "P" and
TapDwl (#1313) is valid.
No dwell executed if
both values are 0.
Wait until time in
left column has
elapsed.
Wait until
completion of
in-position
check by
G1inps value.
Wait until completion
of in-position check
by G0inps value.
1 1
0
1
Larger value of "P" and
TapDwl (#1313) is valid.
No dwell executed if
both values are 0.
Wait until dwell
time in left column
has elapsed after
completion of
in-position check.
Wait until completion
of in-position check
by G0inps value.
1 1
1
1
Larger value of "P" and
TapDwl (#1313) is valid.
Processing time is
several 10ms if both
values are 0.
Wait until dwell
time in left column
has elapsed after
completion of
in-position check.
Wait until
completion of
in-position
check by
G1inps value.
Wait until completion
of in-position check
by G0inps value.
1 0
0
0
Larger value of "P" and
TapDwl (#1313) is valid.
No dwell executed if
both values are 0.
Wait until time in
left column has
elapsed.
1 0
1
0
Larger value of "P" and
TapDwl (#1313) is valid.
No dwell executed if
both values are 0.
Wait until time in
left column has
elapsed.
Wait until
completion of
in-position
check by
G1inps value.
1 1
0
0
Larger value of "P" and
TapDwl (#1313) is valid.
No dwell executed if
both values are 0.
Wait until dwell
time in left column
has elapsed after
completion of
in-position check.
1 1
1
0
Larger value of "P" and
TapDwl (#1313) is valid.
Processing time is
several 10ms if both
values are 0.
Wait until dwell
time in left column
has elapsed after
completion of
in-position check.
Wait until
completion of
in-position
check by
G1inps value.
(Note 1)
The I point refers to the initial point.
Remarks:
The processing time is several 10ms when an in-position check is not carried out at the hole bottom.
The processing time is between 0 to 14.2ms when an in-position check is not carried out at the R
point.
The processing time is the spindle gain changeover time when an in-position check is not carried out
at I point
→
R point.