13. Program Support Functions
13.1 Fixed Cycles
255
Operation1
Operation4
Opera-
tion7
Opera-
tion6
Operation5
-10.
Opera-
tion12
Operation8
Opera-
tion11
Opera-
tion10
Operation9
-10.
Operation2
Operation3
-50.
Operation
pattern
,I ,J
Operation 1
Valid
–
Operation 2
–
Invalid
Operation 3
–
Invalid
Operation 4
–
Valid
Operation 5
Invalid
–
Operation 6
–
Invalid
Operation 7
–
Invalid
Operation 8
–
Valid
Operation 9
Valid
–
Operation 10
–
Invalid
Operation 11
–
Invalid
Operation 12
–
Valid
Fig. 2 Operation in fixed cycle modal
Setting values of synchronous tap in-position check parameters and tap axis movement
(1) Synchronous tap in-position check settings
#1223 aux07
Bit3 Bit4
Bit5
Bit2
Synchronous
tapping
in-position
check
At hole
bottom
At
R point
I point
→
R point
"P" designation of
G84/G74 command
In-position check
during synchronous tapping
0 —
—
—
—
Carry out in-position check at I point
→
R point/R
point/hole bottom.
1 —
—
—
No "P" designation
Example
: G84 F1. Z-5.
S1000
R-5.
Hole bottom:
R point:
I point
→
R point:
Do not carry out in-position check.
Do not carry out in-position check.
Do not carry out in-position check.
1 1
1
1
"P" designation
Example
: G84 F1. Z-5.
S1000
PO
R-5.
Hole bottom:
R point:
I point
→
R point:
Carry out in-position check by tap
in-position width.
Carry out in-position check.
Carry out in-position check.
1 1
0
1
"P" designation
Example
: G84 F1. Z-5.
S1000
PO
R-5.
Hole bottom:
R point:
I point
→
R point:
Carry out in-position check by tap
in-position width.
Do not carry out in-position check.
Carry out in-position check.
1 0
1
1
"P" designation
Example
: G84 F1. Z-5.
S1000
PO
R-5.
Hole bottom:
R point:
I point
→
R point:
Do not carry out in-position check.
Carry out in-position check.
Carry out in-position check.
1 0
0
1
"P" designation
Example
: G84 F1. Z-5.
S1000
PO
R-5.
Hole bottom:
R point:
I point
→
R point:
Do not carry out in-position check.
Do not carry out in-position check.
Carry out in-position check.
1 1
1
0
"P" designation
Example
: G84 F1. Z-5.
S1000
PO
R-5.
Hole bottom:
R point:
I point
→
R point:
Carry out in-position check by tap
in-position width.
Carry out in-position check.
Do not carry out in-position check.
1 1
0
0
"P" designation
Example
: G84 F1. Z-5.
S1000
PO
R-5.
Hole bottom:
R point:
I point
→
R point:
Carry out in-position check by tap
in-position width.
Do not carry out in-position check.
Do not carry out in-position check.
1 0
1
0
"P" designation
Example
: G84 F1. Z-5.
S1000
PO
R-5.
Hole bottom:
R point:
I point
→
R point:
Do not carry out in-position check.
Carry out in-position check.
Do not carry out in-position check.
1 0
0
0
"P" designation
Example
: G84 F1. Z-5.
S1000
PO
R-5.
Hole bottom:
R point:
I point
→
R point:
Do not carry out in-position check.
Do not carry out in-position check.
Do not carry out in-position check.
(Note 1)
The I point refers to the initial point.