Appendix-640
Spline interpolation
(7) Details of path point data
The details of the path point data registered in the spline file are explained below.
Table 7-12:Details of path point data
Tools
Position
jump
A dedicated screen for position jump function opens.
Interpolation
settings
The spline file Interpolation Setting screen opens.
Ex-T control
settings
The spline file Ex-T control setting screen opens.
Position
adjustment
The dedicated screen for the position adjustment function
opens.
Frame trans-
formation
A dedicated screen for the frame transformation function
opens.
Motion range
check
Checking whether the spline file being edited is within the oper-
ating range of the robot or not.
* This function can be executed in the simulations.
Path point
check
A dedicated screen for path point check function opens.
Calculate
maximum
speed
Calculates the maximum speed which can be specified without
an error in the spline interpolation commands using the spline
file being edited.
Spline curve
The spline curve registered in the spline file being edited is dis-
played.
Robot pro-
gram - Con-
vert to
program
Converts the spline file being edited to the robot program.
Robot pro-
gram -
Import posi-
tion variables
Imports the position data registered in the robot program to the
spline file being edited.
Note1) MXT file is a file that contains the dot sequence data and outputted by MELFA-Works.
Data item
Details
Default value when
newly added
Position
Designate the path point position data with the Cartesian coordinate
system (Y, Z, A, B, C, L1, L2, FLG1, FLG2).
The distance unit is mm and the angle unit is deg.
X to L2: 0.0
FLG1: Left, Below, Flip
FLG2: 0
Arc designation
Designate the path points for the arc path.
Setting range: Check (designation enabled), No check (designation
invalid)
No check
Tolerance
Position
Designate the tolerance for the position (path).
Setting range: 0 to 100 [%]
100
Posture
Designate the tolerance for the posture.
Setting range: 0 to 100 [%]
100
Status variable
Designate the value referred to by status variable M_SplVar.
Setting range: –1 to 32767 (–1 means not set.)
-1
Menu item
Explanation
Reference
page