Explanation of operation methods
Operating the monitor screen
3-79
3) The current output value of No. 8000 is displayed by the decimal number in the parenthesis following
the output value. The value in the parenthesis following lower 0x is the hexadecimal number.
If the function key which corresponds for "CLOSE" is pressed, it can also return to the monitoring
screen on the basis of No. 8000 of the output register, but the output value can be changed on the
current screen.
The case where the value of the output register No. 8000 is set as 12 (decimal number) is shown in
the following.
4) The setup of the value can be set up by the decimal number or the hexadecimal number.
If it sets up by the decimal number, move the cursor to the output value by the arrow key, and input
"10". The unnecessary character should press and erase the [CLEAR] key.
If it sets up by the hexadecimal number, move the cursor to 0x by the arrow key, and input "C". The
unnecessary character should press and erase the [CLEAR] key.
Press the function key ([F1]) corresponding to the "OUTPUT", then will actually output the set-up
value.
5) Press the function key corresponding to "CLOSE", and return to the output register monitor screen.
6) Press the function key corresponding to "CLOSE", and return to the output menu screen.
<OUTPUT REGISTER>
START No. (
8000
)
OUT.VALUE ( 0 )
0x( 0000 )
CLOSE
123
OUTPUT
<OUTPUT REGISTER>
START No. (
8000
)
OUT.VALUE ( 10 )
0x( 000C )
CLOSE
123
OUTPUT
<OUTPUT REGISTER>
START No. (
8000
)
OUT.VALUE ( 0 )
0x( 0000 )
CLOSE
123
OUTPUT
<OUTPUT REGISTER>
8000 0 0×0000
8001 0 0×0000
8002 0 0×0000
8003 0 0×0000
CLOSE
123
NUMBER
Prev
Next
<OUTPUT REGISTER>
START No. (
8000
)
OUT.VALUE ( 10 )
0x( 000C )
CLOSE
123
OUTPUT
<OUTPUT REGISTER>
6000 0 0×0000
6001 0 0×0000
6002 0 0×0000
6003 0 0×0000
CLOSE
123
NUMBER
Prev
Next
<MONITOR>
1.INPUT
2.OUTPUT
3.INPUT REG. 4.OUTPUT REG.
5.VARIABLE 6.ERROR LOG
CLOSE
123