![Mitsubishi Electric CR750 Series Скачать руководство пользователя страница 588](http://html.mh-extra.com/html/mitsubishi-electric/cr750-series/cr750-series_instruction-manual_238840588.webp)
6-568
Dedicated input/output
6External input/output functions
PSOUT
Input
Position data output
specification
Specifications are made so that specified posi-
tion number data for specified slot number is
outputted.
Position data is updated when specified signal
is turned ON. Input signal level is "level," but
position data remains un-updated whenever
the signal stays ON. Information is updated
upon the signal being turned ON.
0(OFF): Position data is not required to be out-
putted or position number is being speci-
fied.
1(ON): Position data output demanded.
Level
-1,-1
Output Position data being out-
putted
Output is made to indicate that specified posi-
tion data has been outputted.
[Output information]
0(OFF): Position data not yet outputted
1(ON): Position data being outputted
PSPOS
Input
-
-
-
-1 (Not significant)
-1
Output Specified position data Specified position data is outputted by using
signals consisting of 32 bits for 8 axes plus 32
bits for 2 elements (structural flags) derived
from signal numbers specified under this
parameter (320 bits are used).
The range of the setting value:
(1)CR7xx-Q series
10000 ~ 17872: Multi-CPU share device
(2)CR7xx-D series
2000 ~ 3632: Profibus
6000 ~ 7728: CC-Link
Unit of each component value for position data
expressed by a 32-bit signal is micrometer
(um) = 10
-3
mm or 10
-3
degree.
Take note that outputted data comes as a
signed integer (-2
31
~ 2
31
-1).
However, structural flags are outputted in the
form of values they carry without being con-
verted in terms of micrometer.
Position type variable: X, Y, Z, A, B, C, L1, L2,
FL1, FL2
Joint type variable: J1, J2, J3, J4, J5, J6, J7,
J8
If an error occurs in slot number,
"0x7FFFFFFF" is outputted. If an error occurs
in position number, "0x80000000" is outputted.
Since the time chart and precautions are
shown in
Page 584, "(5) Example of external
operation timing chart (Part 5)"
, refer to it.
TMPOUT
Input
Temperature output
request
The temperature inside the robot controller is
output to the numerical output (IODATA).
After the start of inputting this signal to the
robot, wait at least
15 ms before reading the numerical output
(IODATA) signal
Edge
-1,-1
Output Temperature output sig-
nal
The "temperature output in progress" status is
output to the numerical output.
-
RSTBAT
Input
Battery cumulative time
reset
Reset the battery cumulative tine.
-
-1,
-1
Output Reset is completed
Output that the reset has been completed.
Parameter
name
Class
Name
Function
Signal
level
Note1)
Factory shipment signal number.
Input, output
CR7xx-Q
CR7xx-D