![Mitsubishi Electric CR750 Series Скачать руководство пользователя страница 266](http://html.mh-extra.com/html/mitsubishi-electric/cr750-series/cr750-series_instruction-manual_238840266.webp)
4-246
Detailed explanation of command words
JOvrd (J Override)
[Function]
Designates the override that is valid only during the robot's joint movements.
[Format]
[Terminology]
<Designated override>
Describe the override as a real number.
A numeric operation expression can also be described.
Unit: [%] (Recommended range: 1 to 100.0)
[Reference Program]
1 JOvrd 50
2 Mov P1
3 JOvrd M_NJovrd
' Set the default value.
[Explanation]
(1) The JOvrd command is valid only during joint interpolation.
(2) The actual override is = (Operation panel (T/B) override setting value) x (Program override (Ovrd com-
mand)) x (Joint override (JOvrd command)). The JOvrd command changes only the override for the joint
interpolation movement.
(3) The 100% <Designate override> is the maximum capacity of the robot. Normally, the system default
value (M_NOvrd) is set to 100%. The value is reset to the default value when the End statement is exe-
cuted or the program is reset.
[Related instructions]
,
[Related system variables]
M_NJovrd (System default value), M_JOvrd (Currently specified joint override)
JOvrd[]<Designated override>