![Mitsubishi Electric CR750 Series Скачать руководство пользователя страница 666](http://html.mh-extra.com/html/mitsubishi-electric/cr750-series/cr750-series_instruction-manual_238840666.webp)
Appendix-646
Spline interpolation
Fig.7-59:Circular interpolation
■
Interpolation settings
Set the "Operation mode", "Cancel angle" and "Straight ratio" for the spline interpolation.
When the menu [Tool]
→
[Interpolation settings] is clicked, the interpolation settings set in the spline file on
the active Spline File Edit screen appear in the setting screen.
Fig.7-60:Interpolation settings screen
If the [OK] button is clicked after changing the settings, the changes will be saved and the setting screen will
close. If the [Cancel] button is clicked, the setting screen will close without saving the changes. The setting
range for each item is shown in
.
Table 7-14:Setting range for interpolation setting items
Item
Setting range
Default value
Operation mode
Constant linear speed/variable linear speed
Constant linear speed
Cancel angle
0 to 180 [deg]
120
Straight ratio
0 to 100 [fold]
8