6 INSTALLATION AND WIRING
6.3 Installation
41
6
6.3
Installation
Mounting the modules on a DIN rail
The following procedure is just an example of fixing the module with a DIN rail stopper. When fixing the safety
remote I/O module, refer to the manual of the DIN rail stopper used.
Installation procedure
1.
Pull down the DIN rail hooks on the back of the safety
remote I/O module. The hooks should be pulled down
until they click.
2.
Hang the upper tabs of the module on the upper side of
a DIN rail, and push the safety remote I/O module in
position.
3.
Lock the DIN rail hooks to the DIN rail to secure the
safety remote I/O module in position. Push each hook
up until it clicks. If the hooks are beyond the reach, use
a tool such as a screwdriver.
4.
Loosen the screw on the DIN rail stopper.
5.
Hitch the bottom hook of the DIN rail stopper to the
bottom of the DIN rail. Hitch the hook according to the
orientation of the arrow on the front of the stopper.
Hook
Hook
Hitch the hook to
bottom of the DIN rail