Page 86
Accumass BW500
PL-565
Par
a
m
e
te
rs
P943
Load Cell A/D Reference
Displays the A/D reference value for the selected load cells. These values are
affected by load cell balancing (P295).
Load cells are:
– 01 = A and B
– 02 = C and D
– 03 = A and B plus C and D
– 04 = A
– 05 = B
– 06 = C
– 07 = D
P948
Error Log
Displays a log of the last 25 error or alarm events (P948 – 01 to – 25) that have
occurred. Event 01 is the current error.
Display:
0 = no error
# = error code, refer to Troubleshooting on page 137
P949
Diagnostic Error Testing
Enables or disables diagnostic error checking for memory, load cell and zero speed.
(
f
=0)
Entry:
0 = disable
1 = enable
Refer to Troubleshooting on page 137.
P950
Zero Register
Registers the number of zero calibrations that have been done since the last master
reset.
(
f
=0)
P951
Span Register
Registers the number of span calibrations for the span selected, span 1 to 4 (P951 -
01 to - 04), that have been done since the last master reset.
(
f
=0)
P952
Design Load
Displays the value of the design load, which corresponds to the full scale value for
alarm and mA output functions. The design load is calculated, based on the design
rate and design speed.
(
f
=0.00)
Содержание ACCUMASS BW500
Страница 1: ...ACCUMASS BW500 Instruction Manual PL 565 January 2001 CCUMASS BW500 33455650 Rev 1 2...
Страница 6: ...Page 6 Accumass BW500 PL 565...
Страница 12: ...Page 12 Accumass BW500 PL 565 Specifications...
Страница 28: ...Page 28 Accumass BW500 PL 565 Installation...
Страница 88: ...Page 88 Accumass BW500 PL 565 Parameters...
Страница 94: ...Page 94 Accumass BW500 PL 565 Operation...
Страница 106: ...Page 106 Accumass BW500 PL 565 PID Control...
Страница 110: ...Page 110 Accumass BW500 PL 565 Batching...
Страница 112: ...Page 112 Accumass BW500 PL 565 Certification...
Страница 140: ...Page 140 Accumass BW500 PL 565 Appendices...