Page 118
Accumass BW500
PL-565
Communic
a
tion
This parameter allows for reconnection to the BW500 unit after an unexpected
disconnect. Ensure that the value is low enough to avoid unnecessary delays when
an unexpected disconnect occurs but long enough to avoid timeout while you are still
legitimately connected.
Hanging Up
If the line is idle and the P779 Modem Inactivity Timeout expires then the modem is
directed to hang up the line. This is done with the Hayes commands:
•
two second delay
•
+++
•
two second delay
•
ATH
Ensure that P779 is set longer than the standard polling time of the connected master
device.
0 disables the inactivity timer.
Values
0-9999: 0
(
f
=1)
P780 RS-232 transmission interval
Note:
Applicable only to ports programmed for printer communication (parameter 770).
Sets the interval between transmissions to be applied to the selected port, ports 1 to
3 (P780-01 to –03).
Enter the period in minutes.
(
f
=0)
P781 data message
Note:
Applicable only to ports programmed for printer communication (parameter 770).
Sets the data message to be delivered via the selected port, ports 1 to 3 (P781-01 to
–03).
All messages and printouts include time and date.
Entry:
0 = no message
f
1 = rate
2 = total*
3 = load
4 = speed
5 = rate, total*, load and speed
6 = rate and total*
Содержание ACCUMASS BW500
Страница 1: ...ACCUMASS BW500 Instruction Manual PL 565 January 2001 CCUMASS BW500 33455650 Rev 1 2...
Страница 6: ...Page 6 Accumass BW500 PL 565...
Страница 12: ...Page 12 Accumass BW500 PL 565 Specifications...
Страница 28: ...Page 28 Accumass BW500 PL 565 Installation...
Страница 88: ...Page 88 Accumass BW500 PL 565 Parameters...
Страница 94: ...Page 94 Accumass BW500 PL 565 Operation...
Страница 106: ...Page 106 Accumass BW500 PL 565 PID Control...
Страница 110: ...Page 110 Accumass BW500 PL 565 Batching...
Страница 112: ...Page 112 Accumass BW500 PL 565 Certification...
Страница 140: ...Page 140 Accumass BW500 PL 565 Appendices...