Page 70
Accumass BW500
PL-565
Par
am
et
e
rs
P360
Calibration Duration
Sets the number of whole belt revolutions to be used during a zero or span
calibration.
(
f
=1)
Enter number of belt revolutions, range 1 to – 99
P365
Multispan
Select the span reference to be applied for determination of rate and totalization.
Entry:
1 = multispan 1 (MS1), for product or condition A
f
2 = multispan 2 (MS2), for product or condition B
3 = multispan 3 (MS3), for product or condition C
4 = multispan 4 (MS4), for product or condition D
5 = multispan 5 (MS5), for product or condition E
6 = multispan 6 (MS6), for product or condition F
7 = multispan 7 (MS7), for product or condition G
8 = multispan 8 (MS8), for product or condition H
Refer to Multispan on page 50 and P270, Auxiliary Input Function (6) on page 67.
P367
Direct Zero Entry
Directly enters the zero reference count
Direct entry is intended for use when replacing software or hardware and it is not
convenient to perform an initial zero at that time.
(
f
=0)
Refer to Recalibration on page 41 for execution.
P368
Direct Span Entry
Directly enters the span reference count for the span selected, span 1 to 8 (P368-01
to -08).
Direct entry is intended for use when replacing software or hardware and it is not
convenient to perform an initial span at that time.
(
f
=0)
Refer to Recalibration on page 41 for execution.
P370
Zero Limit Deviation %
Sets the zero calibration deviation limit (
±
) from the last initial zero. If the
accumulated deviation of successive zero calibrations exceeds the limit, the zero
calibration is aborted.
(
f
=12.5)
Note:
If the ‘legal for trade’ certification switch has been set, the zero limit is
±
2%.
Enter the maximum allowable % deviation
Содержание ACCUMASS BW500
Страница 1: ...ACCUMASS BW500 Instruction Manual PL 565 January 2001 CCUMASS BW500 33455650 Rev 1 2...
Страница 6: ...Page 6 Accumass BW500 PL 565...
Страница 12: ...Page 12 Accumass BW500 PL 565 Specifications...
Страница 28: ...Page 28 Accumass BW500 PL 565 Installation...
Страница 88: ...Page 88 Accumass BW500 PL 565 Parameters...
Страница 94: ...Page 94 Accumass BW500 PL 565 Operation...
Страница 106: ...Page 106 Accumass BW500 PL 565 PID Control...
Страница 110: ...Page 110 Accumass BW500 PL 565 Batching...
Страница 112: ...Page 112 Accumass BW500 PL 565 Certification...
Страница 140: ...Page 140 Accumass BW500 PL 565 Appendices...