Troubleshooting
Generally
1.
First check to see that:
a.
There is power at the unit
b.
The LCD is showing something
c.
The device can be programmed using the fixed keypad.
2.
Then, check the wiring pin outs and verify that the connection is correct.
3.
Next, go over the setup parameter P770 to P779 and verify that these values match
the settings in the computer that you are using to communicate with it.
4.
Finally, if you should check that the port you are using on the computer. Sometimes
trying a different Modbus driver will solve the problem. An easy stand-alone driver
called ModScan32, is available from Win-Tech at www.win-tech.com. We have found
that this driver has been very useful to test communications.
Specifically
Q1:
I tried to set a Milltronics device parameter, but the parameter remains unchanged.
A1.1:
a.
Try setting the parameter from the keypad. If it can’t be set using the
keypad, check the lock parameter (P000) and,
b.
Check to ensure that the SW1 (certification switch) is not in the
certification position.
Содержание ACCUMASS BW500
Страница 1: ...ACCUMASS BW500 Instruction Manual PL 565 January 2001 CCUMASS BW500 33455650 Rev 1 2...
Страница 6: ...Page 6 Accumass BW500 PL 565...
Страница 12: ...Page 12 Accumass BW500 PL 565 Specifications...
Страница 28: ...Page 28 Accumass BW500 PL 565 Installation...
Страница 88: ...Page 88 Accumass BW500 PL 565 Parameters...
Страница 94: ...Page 94 Accumass BW500 PL 565 Operation...
Страница 106: ...Page 106 Accumass BW500 PL 565 PID Control...
Страница 110: ...Page 110 Accumass BW500 PL 565 Batching...
Страница 112: ...Page 112 Accumass BW500 PL 565 Certification...
Страница 140: ...Page 140 Accumass BW500 PL 565 Appendices...