PL-565
Accumass BW500
Page 127
Communic
a
tions
If the numeric data type is set for integer and the value contains decimal places they
are ignored. In this situation use the decimal offset to ensure that you have an integer
value and then write your code to recognize and handle the decimal offset. Bits 9 to
11 indicate the number of place by which the decimal is to be shifted. Bit 12 indicates
the direction by which the decimal point is shifted, left or right. For example, if the
decimal offset (value of bits 9 to 11) is ‘2’ and the shift (value of bit 12 is ‘0’), then the
decimal point is shifted two places to the right.
Error Codes
The error codes returned in the format area are 8-bit integers found in the lowest 8
bits of the format word. This allows for 256 potential error codes.
Currently the BW500 has two error codes available.
Values
Description
0
No error
1
Data not available as percent (available as units)
2-255
Reserved
Date and Time (R41,000 – 41,006)
The date and time can be read or written in registers 41,000 to 41,006 as defined in
the table above.
Example: : If you are located in Toronto, Canada and would like to set the date and
time to February 14, 1999, 1:30 p.m. and 42 seconds, you would write the following:
Register
Value
R41,000
1999
R41,001
2
R41,002
14
R41,003
13
R41,004
30
R41,005
42
R41,006
-5
Note:
The time zone register is used only as a reference, and does not affect the
operation of the BW500.
Process Values (R41,010 – R41,048)
Rate, Load, Speed and Total (R41,010 – R41,019)
The associated registers provide the readings of rate, load, and speed. Totalizer 1
and Totalizer 2 in engineering units as displayed in the local BW500 display.
Содержание ACCUMASS BW500
Страница 1: ...ACCUMASS BW500 Instruction Manual PL 565 January 2001 CCUMASS BW500 33455650 Rev 1 2...
Страница 6: ...Page 6 Accumass BW500 PL 565...
Страница 12: ...Page 12 Accumass BW500 PL 565 Specifications...
Страница 28: ...Page 28 Accumass BW500 PL 565 Installation...
Страница 88: ...Page 88 Accumass BW500 PL 565 Parameters...
Страница 94: ...Page 94 Accumass BW500 PL 565 Operation...
Страница 106: ...Page 106 Accumass BW500 PL 565 PID Control...
Страница 110: ...Page 110 Accumass BW500 PL 565 Batching...
Страница 112: ...Page 112 Accumass BW500 PL 565 Certification...
Страница 140: ...Page 140 Accumass BW500 PL 565 Appendices...