Page 56
Accumass BW500
PL-565
Recal
ib
rat
io
n
Program the BW500 as follows:
Parameter
Function
P390 = 1,
linearization – on
P391-01 = 6.94
point 1, load
P391-02 = 13.89,
point 2, load
P391-03 = 20.83
point 3, load
P391-04 = 27.78
point 4, load
P391-05 = 34.72
point 5, load
P392-01 = - 10.7
point 1, compensation
P392-02 = 11.1
point 2, compensation
P392-03 = - 5.1
point 3, compensation
P392-04 = 8.7
point 4, compensation
P392-05 = -6.0
point 5, compensation
Note:
Often only one point of compensation is required, usually at a low load value. In
the prior example, if compensation was only required at 6.94 kg/m, the
programming could be as follows. Compensation is optimized by establishing the
next load value that agrees with the material test, hence where compensation is
zero and entering it as the next compensation point.
P390 = 1
linearization on
P391-01 = 6.94
point 1, load
P391-02 = 20.00
point 2, load
P392-01 = -10.7
point 1, compensation
P392-02 = 0
point 2, compensation
actual weight per material test
totalized weight by BW500
belt scale response
linearized BW500 response
internal response, 100-150% of span
% compensation
span (100%)
-10.7
♦
We
ight
= T
onn
es
Load – kg / m
Содержание ACCUMASS BW500
Страница 1: ...ACCUMASS BW500 Instruction Manual PL 565 January 2001 CCUMASS BW500 33455650 Rev 1 2...
Страница 6: ...Page 6 Accumass BW500 PL 565...
Страница 12: ...Page 12 Accumass BW500 PL 565 Specifications...
Страница 28: ...Page 28 Accumass BW500 PL 565 Installation...
Страница 88: ...Page 88 Accumass BW500 PL 565 Parameters...
Страница 94: ...Page 94 Accumass BW500 PL 565 Operation...
Страница 106: ...Page 106 Accumass BW500 PL 565 PID Control...
Страница 110: ...Page 110 Accumass BW500 PL 565 Batching...
Страница 112: ...Page 112 Accumass BW500 PL 565 Certification...
Страница 140: ...Page 140 Accumass BW500 PL 565 Appendices...