Page 72
Accumass BW500
PL-565
Par
am
et
e
rs
Linearization Parameters (P390 - P392)
These parameters are used to compensate for non-linear response of the weighing
system to the BW500. Refer to Linearization on page 54 for execution, and example
on the use of these parameters.
Note:
In the case of multispan operation, the linearizer is applied to all spans.
P390
Linearizer
Enables or disables the linearization function.
Entry:
0 = off
f
1 = on
P391
Linearizer Load Points
Enters the load values, in units of P017, for the point selected, points 1 to 5 (P391-01
to –05).
(
f
=0.00)
P392
Linearizer Compensation %
Enters the compensation value, in percent, for the point selected, point 1 to 5 (P392-
01 to – 05).
(
f
=0.00)
P398
Moisture
Factors out moisture component of load, rate and total for all multispans selected.
The factored values are meant to report the dry mean values of the material being
conveyed.
(
f
=0.00)
Enter the moisture content in % weight.
Содержание ACCUMASS BW500
Страница 1: ...ACCUMASS BW500 Instruction Manual PL 565 January 2001 CCUMASS BW500 33455650 Rev 1 2...
Страница 6: ...Page 6 Accumass BW500 PL 565...
Страница 12: ...Page 12 Accumass BW500 PL 565 Specifications...
Страница 28: ...Page 28 Accumass BW500 PL 565 Installation...
Страница 88: ...Page 88 Accumass BW500 PL 565 Parameters...
Страница 94: ...Page 94 Accumass BW500 PL 565 Operation...
Страница 106: ...Page 106 Accumass BW500 PL 565 PID Control...
Страница 110: ...Page 110 Accumass BW500 PL 565 Batching...
Страница 112: ...Page 112 Accumass BW500 PL 565 Certification...
Страница 140: ...Page 140 Accumass BW500 PL 565 Appendices...