Fieldbus Configuration file – PI and PI PLASMA - Std. for Motoman
Program change and current setting from RCI
2
- 10010607
AnyBus Configuration
–
10010607 v1.20
PI
–
Standard for Motoman
10010607.doc
Page 3 of 3
OUTPUT BYTES from RCI
2
Byte#
Bit#
Name
–
Description
–
Example
1
–
2
1
–
16
Actual Welding Voltage
–
for AVC
Returns the arc voltage when current is slow pulsating: indicated for AVC [1 unit = 0,1Volt]
Example: 325
32,5Volts
3
–
4
17
–
32
Actual Welding Current
Returns the value of Welding Current [1 unit = 0,1Amp]
Example: 1900
190,0 Amp
5
–
6
33
–
48
Actual Shield Gas flow rate
Returns the SHIELD gas flow rate. [Litres/min*100]
Example: 600
6,0 Litres/min
7
–
8
49
–
64
Actual Plasma gas flow
Returns the PLASMA gas flow rate. [Litres/min*100]
Example: 450
4,5 Litres/min
9
–
10
65
–
80
Actual Wire speed
Returns the speed of wire for the CWF in use on Pi. [mm/min]
Example: 2500
2,5m/min
11
81
–
88
Reserved for system
12
89
–
96
Actual program number selected
Returns the welding program number in use on machine
Example: 21
Program #21
13
97
–
104
Status bits
Bit #97
–
Arc Detect. ON when Arc is established
Bit #98
–
(not used)
Bit #99
–
Touch Sense. ON when the Touch Sense input is on, and the electrode is touching the work
piece
Bit #100
–
Stick Control. ON when the electrode is touching the work piece.
Bit #101
–
Pilot Arc Detect. ON when Pilot Arc is established.
Bit #102
–
Process Active. Machine is welding, or purging shield gas.
Bit #103
–
Shield Gas Fault. There is an error in flow of the Shield gas.
Bit #104
–
Plasma Gas Fault. There is an error in the flow of the Plasma gas.
14
105 - 112
Status bits
Bit #105
–
Machine Ready. Machine is ready to weld.
…
Bit #106 - #112
–
(not used)