58
59
Fieldbus Configuration file – Sigma Galaxy - Standard
Sigma Galaxy - 10010205
AnyBus Configuration – 10010205 v1.02
Sigma – Standard
10010205
Page 1 of 3
Notes regarding representation of numbers and range of values
1) ALL numbers are UNSIGNED, 1 or 2 bytes (8 or 16 bits). Control bits can be accessed at bit level.
2) The values for each parameter have to be according to the welding machine in use: they will be ignored if
out of range.
INPUT BYTES to RCI
2
Byte
#
Bit#
Name – Description – Example
1 – 2
1 - 16
Set Welding Voltage Trim
Set the value of the welding voltage trim [V*50 + 500].
Example: 400
-2.0V; 500
0.0V; 860
+7.2V
Welding voltage trim cannot be controlled from interface, if machine is in job mode.
Range: 0 – 100 = -9.9 to +9.9V
3 - 4
17 – 32
Set Welding Current
Set the value of the welding current [A*10].
Example: 0
0A; 500
50A; 3620
362A
Welding current cannot be controlled from interface, if machine is in job mode.
Range: 0A to Imax for the actual programme
5 - 6
33 – 48
Set Wire Inch Speed
Set the value of the wire inch speed [cm/min*10].
Example: 5
0.5cm/min; 125
12.5cm/min
Minimum inch speed is 0.5cm/min.
Range: 0 to 30m/Min
7 - 8
49 – 64
Job Number Index
Set the job number index
#0 = Normal mode (not job mode)
#1 - #255 = Selecting job with index number #xxx
Example: 3
job index 3
If an index with no associated job is chosen, the welding machine will show an error
(E29-05). Selecting a valid index will clear this error.
Range: 1 to 255
9 - 10
65 - 80
Welding Program
Set the welding program
#005 - #999 = Selecting welding program Pxxx
Example: 112
P112
If a non-existent or non-licensed welding program is chosen, the welding machine will
show an error (E07-14). Selecting a valid program will clear this error.
Welding program cannot be controlled from interface, if machine is in job mode.
Range: Please look at the program table for the actual machine
11 - 12
81 – 96
Sequence Number
Set sequence
#0 = Sequence mode not selected
#01 - #99 = Selecting sequence number #xx
Example: 3
sequence 3
Range: If not running in job mode it is only possible to select up to 9 sequences.
If running in job mode, the maximum number of sequences is defined in the job
(up to 99).
If a non-valid sequence is chosen, the welding machine will show an error (E07-13).
Selecting a valid sequence will clear this error.
13 - 14
97 – 112
Wire feeder
Select wire feeder
#0 = Internal wire feeder
#xx = External wire feeder xx. At the moment only #1 and #2 are valid feeders.
If a second feeder is present, it must be set as No #2 with a jumper inside the feeder.
Example: 1
wire feeder 1. External Wire feeders are standard delivered as No#1.
If a non-existing wire feeder is chosen, the welding machine will show an error (E07-
03). Selecting a valid program will clear this error.
Содержание RCI2
Страница 1: ...USER GUIDE ROBOT CONTROL INTERFACE RCI2 50115001 C1 Valid from 2019 week 24...