ERROR LIST
Error code Problem
Solution
E.70
[BOOT] Invalid or no software in RCi
2
- Install firmware via SD/smart-card.
- Check PLD
E.71
[BOOT] Invalid or no software on SD card or SD
card is defect
- Check reader connection, remove and reinsert smart-
card
- Replace or rewrite SDcard
- Check PLD
E.72
[BOOT] Error flashing software
- Retry flashing removing and reinsert SD card
- On persistent error exchange RCI
2
PCB.
E.73
[BOOT] Fatal hardware error
- Exchange RCI
2
PCB 71617074
E.74
[BOOT] The bootloader is unable to find a valid
application on the SD card
- Check that file \MIGA_SW\ROBOT\10020117.cry is present
on the SD card
- Check PLD
E.75
[BOOT] The bootloader found more than one
valid application on the SD card
- Check that only one file with the name 10020117.cry is
placed in the SD card folder \MIGA_SW\ROBOT
E.02-02
CAN receive buffer overrun because of missing
CAN connection
Check all CAN connections
E.02-03
CAN gone to BUS-OFF state because of missing
CAN connection
Check all CAN connections
- 11V CAN supply is missing
E.02-13
CAN gone to BUS-WARNING state because of
missing CAN connection
Check all CAN connections
E.02-19
CAN interrupt error
- Check the setup of RCI
2
E.02-20
CAN task unknown state
- Check the setup of RCI
2
E.06-50
Memory hardware error
- Exchange RCI
2
PCB 71617074
E.06-51
Lost settings and programs.
Error on Memory data checksum
- Try to recall factory setting
- check Ur option and recalibrate.
- Exchange RCI
2
PCB 71617074
E.06-52
Real-Time-Clock hardware error.
- Exchange RCI
2
PCB 71617074
E.06-53
This error shows up the first time a new PCB is
powered up.
Error on date/time setting
- Set the date and time. See page 26
- Exchange the lithium battery CR2031
- Exchange RCI
2
PCB 71617074
E.07-30
Accessed PCB test mode
Information only
E.07-31
Executed factory-reset from PCB test
Information only
E.12-10
User has accessed service menu
Information only
E.12-13
User has executed Factory-Reset from service
menu
Information only
E.12-19
Error in user interface
- Check the setup of RCI
2
E.12-56
Accessed PCB test mode
Information only
E.12-57
Executed factory-reset from PCB test
Information only
Содержание RCI2
Страница 1: ...USER GUIDE ROBOT CONTROL INTERFACE RCI2 50115001 C1 Valid from 2019 week 24...