74
75
ANYBUS - ERROR LIST
EtherCAT
Ethernet Connector
#
Item
1
RUN LED
2
ERROR LED
3
EtherCAT (port 1)
4
EtherCAT (port 2)
5
Link/Activity (port 1)
6
Link/Activity (port 2)
RUN LED
This LED reflects the status of the CoE (CANopen over EtherCAT) communication
LED State
Indication
Description
Off
INIT
CoE device in ‘INIT’-state (or no power)
Green
OPERATIONAL
CoE device in ‘OPERATIONAL’-state
Green, blinking
PRE-OPERATIONAL
CoE device in ‘PRE-OPERATIONAL’-state
Green, single flash
SAFE-OPERATIONAL
CoE device in ‘SAFE-OPERATIONAL’-state
Red
a
(Fatal Event)
-
a. If RUN and ERR turns red, this indicates a fatal event, forcing the bus interface to
a physically passive state. Contact HMS technical support
ERR LED
This LED indicates EtherCAT communication errors etc.
LED State
Indication
Description
Off
No error
No error (or no power)
Red, blinking
Invalid configuration
State change received from master is not
possible due to invalid register or object
settings
Red, double flash
Application watchdog timeout
Sync manager watchdog timeout
Red
a
Application controller failure
Anybus module in EXCEPTION
a. If RUN and ERR turns red, this indicates a fatal event, forcing the bus interface to
a physically passive state. Contact HMS technical support
LINK/Activity
These LEDs indicate the EtherCAT link status and activity
LED State
Indication
Description
Off
No link
Link not sensed (or no power)
Green
Link sensed, no activity
Link sensed, no traffic detected
Green, flickering
Link sensed, activity detected
Link sensed, traffic detected
6