52
53
Sigma Galaxy – Sequence selection and analog input - 10010202
Analog Configuration file – Sigma Galaxy - Sequence selection
Analog Configuration – 10010202 v1.0
Sigma Galaxy – Sequence selection and analog input
10010202
Page 1 of 2
DIGITAL INPUTS (JMP1=Active-HIGH)
Pin# /
Military
Plug
Symbol
Name
Description
Active
1 / m
DIN15
!Quick-Stop
Emergency stop
When input is H the machine can operate.
When input is L the welding will stop instantly without slope
down and the machine cannot start welding.
L
12 / W
DIN4
Wirefeeder-Bit0
Wirefeeder Selection
Select wirefeeder based on inputs combination:
(Bit1)LL(Bit0)
Internal wirefeeder
(Bit1)LH(Bit0)
Wirefeeder 2
(Bit1)HL(Bit0)
Wirefeeder 1
(Bit1)HH(Bit0)
Internal wirefeeder
xx
14 / V
DIN2
Wirefeeder-Bit1
4 / N
DIN12
-
Sequence Selection
Select sequence number based on inputs combination:
(Bit3)LLLL(Bit0)
Normal (not sequence)
mode
(Bit3)LLLH(Bit0)
Select sequence #1
(Bit3)LLHL(Bit0)
Select sequence #2
(Bit3)LLHH(Bit0)
Select sequence #3
…
(Bit3)HLLH(Bit0)
Select sequence #9
When this input has activated sequence mode, sequences
are controlled from the interface, and cannot be controlled
from the welding machine.
xxxx
5 / P
DIN11
-
2 / n
DIN14
-
7 / C
DIN9
Sequence-Bit3
8 / D
DIN8
Sequence-Bit2
9 / G
DIN7
Sequence-Bit1
10 / H
DIN6
Sequence-Bit0
6 / T
DIN10
Tack
Tack Mode On/Off
Set this input H to activate tack. When this input has been
activated once, tack mode is controlled from the interface,
and cannot be controlled from the welding machine.
H
3 / Z
DIN13
Duo Plus
Duo Plus Mode On/Off
Set this input H to activate duo plus. When this input has
been activated once, duo plus mode is controlled from the
interface, and cannot be controlled from the welding
machine.
Duo plus mode cannot be set from interface, if machine is
in job mode.
H
11 / X
DIN5
Pulse
Pulse Mode On/Off
Set this input H to activate pulse. When this input has been
activated once, pulse mode is controlled from the interface,
and cannot be controlled from the welding machine.
Pulse mode cannot be set from interface, if machine is in
job mode.
H
13 / U
DIN3
Wire Inch
Wire Inch On/Off
Set this input H to activate wire inching.
H
15 / S
DIN1
Gas Test
Start Gas Test
Set this input H to start gas test.
H
16 / R
DIN0
Arc Trigger
Start Welding Arc
When input is H welding is started (other tasks as wire-inch,
gas purge etc. are aborted).
If Quick-Stop is active arc is not started.
H
Содержание RCI2
Страница 1: ...USER GUIDE ROBOT CONTROL INTERFACE RCI2 50115001 C1 Valid from 2019 week 24...
Страница 79: ...79...