34
35
Analog Configuration file – PI TIG Standard
PI DC or AC/DC with/without CWF – 10010601
Analog Configuration - 10010601 v1.02
PI DC or AC/DC with/without CWF
10010601
Page 2 of 2
DIGITAL OUTPUTS (JMP3=Active-HIGH)
Pin# /
Military
Plug
Symbol
Name
Description
Active
17 / d
DOUT0 Arc-Detect
Arc-Detect Status
Output is H when welding arc is present.
H
18 / j
DOUT1 Error-Shield-Gas
Shield Gas Error
Output is H when shield gas can not be maintained at set
level (i.e. low pressure, blocked pipes, etc.).
H
19 / k
DOUT2
20 / h
DOUT3 !Error
Global Error Status
Output is H when status is OK.
Output is L when some errors are active (interface, machine
or feeder).
L
21 / e
DOUT4
ANALOG INPUTS
Pin# /
Military
Plug
Symbol
Name
Description
Range
25 / E
AIN0
Wire-Speed(+)
Set CWF Wire Speed*
Control CWF wire speed in real-time:
0V
0
m
/
min
; 10V
5
m
/
min
0-10V
26 / F
Wire-Speed(-)
27 / A
AIN1
Welding-C)
Set Welding Current
Control welding-current in real-time:
0V
0A ; 10V
500A
0-10V
28 / B
Welding-Current(-)
29 / f
AIN2
30 / g
ANALOG OUTPUTS
Pin# /
Military
Plug
Symbol
Name
Description
Range
31 / L
AOUT0 Welding-C)
Read Welding-Arc Current
Measure welding arc current in real-time:
0V
0A ; 10V
1000A
0-10V
32 / M
Welding-Current(-)
33 / J
AOUT1 Welding-
V)
Read Welding-Arc Voltage
Measure welding arc voltage in real-time:
0V
0V ; 10V
100V
0-10V
34 / K
Welding-Voltage(-)
* Inputs working on selected CWF if present
Содержание RCI2
Страница 1: ...USER GUIDE ROBOT CONTROL INTERFACE RCI2 50115001 C1 Valid from 2019 week 24...
Страница 79: ...79...