Troubleshooting
PROBLEM
SOLUTION
The welding current and voltage are instable
It is strongly recommended to keep the digital filter
enabled, Analog Sens=Low. See Setup Menu – IOs
Options.
LOW IMMUNITY, filter disabled, faster response to input
changes – Analog Sens=High
HIGH IMMUNITY, filter enabled, slower response but
higher immunity – Analog Sens=Low
The digital input are instable
It is strongly recommended to keep the digital filter
enabled, Digital Sens=Low. See Setup Menu – IOs
Options
LOW IMMUNITY, filter disabled, faster response to input
changes – Digital Sens=High
HIGH IMMUNITY, filter enabled, slower response but
higher immunity – Digital Sens=Low
No functionality
Check all supply and status LEDs.
5V_CAN.
ON=OK
OFF= 11V CAN supply coming from the
power source is missing. Check CAN cable
5 x supply LEDs
OK=OK
OFF= PCB 71617074 is defect.
Status LESs.
Network error
Check all setups on RCI2
Check all setups on robot/PLC
Check Anybus module
Device error
This information is sent to RCI
2
, because there is a
“legal” error on the welding machine or wire feeder.
Like GAS or TEMP error or Emergency stop is activated.
Check input LED 1.
Correct the error on the welding machine or emergency
stop.
Anybus
Anybus communication activity
CAN
CAN bus communication activity
MICROPROC. RUN
Slow blinking = OK
Fast blinking = General error
Содержание RCI2
Страница 1: ...USER GUIDE ROBOT CONTROL INTERFACE RCI2 50115001 C1 Valid from 2019 week 24...
Страница 79: ...79...