Fieldbus Configuration file – PI and PI PLASMA - Program
Program change from RCI
2
and current setting from PI control box - 10010605
AnyBus Configuration – 10010605 v1.04
PI – Program Select
10010605.doc
Page 1 of 2
Notes regarding representation of numbers and range of values
1) ALL numbers are UNSIGNED, 1 or 2 bytes (8 or 16 bits). Control bits can be accessed at bit level.
2) In case of 2 bytes, for example bytes 1&2, then MSB=Byte#2 and LSB=Byte#1
3) The values for each parameter have to be according to the welding machine in use: they will be ignored if out
of range.
INPUT BYTES to RCI
2
Byte# Bit#
Name – Description – Example
1
1 – 8
Program number.
Select program #1 - #Max by value. Maximum number depends from the machine in use.
By setting #0 the program can be selected directly on the Panel of machine or remote.
Example: Program no = #21
Æ
21
2
9 – 16
Fast pulsation mode
Possibility to enable the Fast Pulsation and select its characteristics
#0 = Fast Pulse Mode is Off
#1 = Fast pulse Mode is On
#4 = Fast pulse Mode is On - Synergic (Pulse frequency depends from the level of current)
Example: Fast Pulse enabled
Æ
1 (most common Fast pulse mode used is #1)
3
17 – 24
Process selection
0 = Tig DC
1 = Tig AC
2 = MMA DC
3 = MMA AC
4 = Plasma DC
Example: Welding Process Plasma DC
Æ
4
4 – 5
25 – 40
Control Bits
Bit #25 – Quick-Stop (1 = stops the welding process)
Bit #26 – E-box Key Lock (1 = lock the box to prevent changes of parameters)
Bit #27 – Arc Start (trigger for Welding Arc)
Bit #28 – Start Pilot Arc (trigger for Pilot Arc).
Plasma gas must be purged manually prior to starting Pilot arc.
(Set Plasma gas value on the Pi front panel, and purge Plasma gas Bit #32
Bit #29 – (not used)
Bit #30 – (not used)
Bit #31 – Shield Gas Purge
Bit #32 – Plasma Gas Purge
Bit #33 – Slow Pulse Enable
Bit #34 – LIFTIG
Bit #35 – Touch Sense
Bit #36 – (not used)
Bit #37 – (not used)
Bit #38 – (not used)
Bit #39 – (not used)
Bit #40 – Tack Welding Enable
6
41 – 48
Control Bits (Control of CWF)
Bit #41 – Wire Hold/Pause
Bit #42 – Wire Inch +
Bit #43 – Wire Inch -
Bit #44 – Disable Pulse Wire
Bit #45 – (not used)
Bit #46 – (not used)
Bit #47 – (not used)
Bit #48 – (not used)
7
49 - 56
Control Bits
Bit #49 – Reset Error – To clear pending errors on the machine, Cold wire feeder or interface
…
Bit #50 - #56 (not used)