A-6
EZ Match User’s Manual
Electrical Specifications
Output Circuit Examples
Fully Optoisolated
This circuit is fully optoisolated and is the
recommended configuration. It allows the
user to apply 1 to 28 VDC to the circuit.
Caution
: The maximum current that can
pass through the optoisolator is 100mA.
Not Optoisolated, Imager Grounded
In this diagram, power is applied externally,
but the scanner’s power ground is used
to complete the circuit. This setup
involves some risk to the optoisolator if
excessive voltages are applied.
Caution
: The maximum current that can
pass through the optoisolator is 100mA.
Additional Output Circuit Examples
Isolated
Host
1 to 28 V
Input
Scanner
Output
Power ground
Outputs (+)
Power (+)
Outputs (–)
Non-isolated
Host
1 to 28 V
Input
Scanner
Output
Power ground
Power (+)
Outputs (–)
Outputs (+)
Isolated
RELAY
Scanner
Output
Power ground
Outputs (+)
Power +
Outputs (–)
1 to 28 V
Secondary Relay
PLC
Isolated
V
PLC
GND
PLC
Input
Scanner
Output
Power ground
Outputs (+)
Power +
Outputs (–)
Содержание EZ Match
Страница 1: ...EZ Match Imager User s Manual P N 83 000044 Rev C...
Страница 12: ...xii EZ Match User s Manual Statement of RoHS Compliance...
Страница 44: ...2 18 EZ Match User s Manual Send Receive Options...
Страница 104: ...4 36 EZ Match User s Manual Postamble...
Страница 122: ...5 18 EZ Match User s Manual Additional Notes about Calibration...
Страница 244: ...8 60 EZ Match User s Manual EZ Trax Output...
Страница 258: ...9 14 EZ Match User s Manual Microscan Symbol Quality Output by ESP...
Страница 270: ...10 12 EZ Match User s Manual New Master Pin...