EZ Match User’s Manual
6-25
Read Cycle
Image Storage
Image Storage Type
Disabled / Clear
Upon selection of this option, all saved images will be cleared and the imager will not store
images for later viewing.
Store on No Read
This option will cause the imager to store an image upon exiting the read cycle for retrieval
at a later time. If multiple captures are present during the duration of a read cycle, the
stored image will be the last image processed for that read cycle. This image is stored in
RAM and can be retrieved as long as power is cycled to the imager, and as long as the
imager has not been reset via a reset/save sequence. Other commands that can initialize
storage in RAM are ones that change capture modes or put the imager in a test capture
mode.
Note:
A
Cap Absence
or
Tube Absence
will qualify for image storage when
Store on No
Read
is selected.
In a
Multi-Operation
read cycle with output set to
As Soon As Possible
, only the results
from the last operation are retained. Therefore, if two operations are active, the first resulting
in a No Read condition and the second
not
resulting in a No Read condition, no image will
be stored.
Definition:
Allows the user to store images from separate read cycles and to retrieve
them later. The number of available slots for storage depends on the mode
of operation. If the imager is in
Rapid Capture Mode
, the number of
images that can be stored is equivalent to the maximum number of the
rapid count (the current rapid count setting). If the imager is in
Continuous
Capture Mode
, a number of images equivalent to the maximum number of
the rapid count minus 3.
Serial Cmd:
<
K244,image storage type
,image storage mode
>
Default:
Disabled/Clear
Options:
0 = Disabled/Clear
1 = Store on No Read
Содержание EZ Match
Страница 1: ...EZ Match Imager User s Manual P N 83 000044 Rev C...
Страница 12: ...xii EZ Match User s Manual Statement of RoHS Compliance...
Страница 44: ...2 18 EZ Match User s Manual Send Receive Options...
Страница 104: ...4 36 EZ Match User s Manual Postamble...
Страница 122: ...5 18 EZ Match User s Manual Additional Notes about Calibration...
Страница 244: ...8 60 EZ Match User s Manual EZ Trax Output...
Страница 258: ...9 14 EZ Match User s Manual Microscan Symbol Quality Output by ESP...
Страница 270: ...10 12 EZ Match User s Manual New Master Pin...
Страница 370: ...15 14 EZ Match User s Manual Ordered Output Filter...