EZ Match User’s Manual
11-7
Camera and IP Setup
Threshold (Histogram)
Enable Autothreshold
is checked by default.
To adjust the threshold manually,
1. Uncheck the
Enable Autothreshold
box.
2. Move the threshold marker (vertical green dashed line) in the
Histogram
chart.
Hint:
This should be midway between the maximum and minimum curves.
3. Click on the
Send Threshold
button to adopt the new threshold position.