8-8
EZ Match User’s Manual
No Read Message
No Read Message
No Read Message Mode
Disabled
Only symbol data is output after a read cycle.
Enabled
When the imager is in a triggered mode, a No Read message will be appended for each
failed read attempt.
Detailed No Read Message
Important:
In the case where the conditions set in
Bad Symbol/No Symbol Qualification
are met, then the
Bad Symbol
or
No Symbol
message output will override the
No Read
Message
or the
Detailed No Read Message
, if either is enabled.
For example, in the following output: “No Read d_1, E_2”, d and E are symbology i.d.s for
Data Matrix and UPC respectively. The message means that Data Matrix and UPC are
enabled (and other symbologies are not), and that both failed to decode. The reason for
the failing Data Matrix is 1 and the reason for the failing UPC is 2. The first part of these
numbers (preceding the dot) is the relevant number and is interpreted here:
2D Symbols:
1. Failed to locate symbol (no finder pattern).
2. Failed to locate four corners or failed to qualify user defined dimensions (in pixels).
3. Failed to locate clock patterns or failed to qualify user-defined orientation (0-359
degrees).
4. Failed to validate clock patterns or failed to qualify user defined symbol size (clock
element count).
5. Failed to decode symbol.
Usage:
Used in applications where the host needs serial verification that a symbol
has not been read and especially useful in new print verification.
Definition:
When enabled, and if no symbol has been decoded before timeout or the
end of the read cycle, the No Read message will be transmitted to the host.
Serial Cmd:
<
K714,No Read message status
,No Read message
>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
2 = Detailed No Read Message
Usage:
Use this option to cover more detailed reasons for decode failures.
Definition:
Outputs a
No Read
message followed by an additional message (an Image
Processing Results Code) indicating the reason a symbol failed to decode.
Содержание EZ Match
Страница 1: ...EZ Match Imager User s Manual P N 83 000044 Rev C...
Страница 12: ...xii EZ Match User s Manual Statement of RoHS Compliance...
Страница 44: ...2 18 EZ Match User s Manual Send Receive Options...
Страница 104: ...4 36 EZ Match User s Manual Postamble...
Страница 122: ...5 18 EZ Match User s Manual Additional Notes about Calibration...
Страница 244: ...8 60 EZ Match User s Manual EZ Trax Output...
Страница 258: ...9 14 EZ Match User s Manual Microscan Symbol Quality Output by ESP...
Страница 270: ...10 12 EZ Match User s Manual New Master Pin...
Страница 370: ...15 14 EZ Match User s Manual Ordered Output Filter...