14-24
EZ Match User’s Manual
Other Operational Serial Commands
Bar Code Configuration Mode
Bar Code Configuration Mode
can be entered three different ways:
1. By forcing the imager into
Bar Code Configuration Mode
by serial command
<BCCFG>
.
2. By configuring one of the 4 EZ Button positions to
Bar Code Configuration Mode
.
3. By reading a Data Matrix symbol with a special code word used by ISO/IEC 16022
to signify imager programming. This can be either in a regular read cycle or during a
Read Rate test. Reading this symbol in the calibration routine will have no effect.
Once
Bar Code Configuration Mode
has been entered, the Data Matrix symbols can be
thought of as serial data. You can configure the imager by printing labels in Microscan’s
serial command format. Commands are processed as if the data were streamed in
through the serial port. The imager will acknowledge the symbol with a beep, green flash,
and echo the serial data to the host. If the command causes the imager to produce more
serial output, such as serial verification or counter requests, the data will be routed to the
host port.
Bar Code Configuration Mode
can be exited by any reset
<A>
or
<Z>
command as well
as a
<J>
or a quick press and release of the EZ Button.
The command to exit
Bar Code Configuration Mode
can be included as part of the Data
Matrix symbol. For example, try encoding
<K200,4><K220,1><J>
into a Data Matrix symbol.
This configures the imager to enable
Serial Trigger Mode
, to program a new trigger to end
the read cycle, and to exit
Bar Code Configuration Mode
with
<J>
.
To end all EZ Button functions, press the EZ Button once and quickly release.
Definition:
Bar Code Configuration Mode
is a way of programming the imager by
using ECC 200 Data Matrix symbols.
Serial Cmd:
<
BCCFG
>
Содержание EZ Match
Страница 1: ...EZ Match Imager User s Manual P N 83 000044 Rev C...
Страница 12: ...xii EZ Match User s Manual Statement of RoHS Compliance...
Страница 44: ...2 18 EZ Match User s Manual Send Receive Options...
Страница 104: ...4 36 EZ Match User s Manual Postamble...
Страница 122: ...5 18 EZ Match User s Manual Additional Notes about Calibration...
Страница 244: ...8 60 EZ Match User s Manual EZ Trax Output...
Страница 258: ...9 14 EZ Match User s Manual Microscan Symbol Quality Output by ESP...
Страница 270: ...10 12 EZ Match User s Manual New Master Pin...
Страница 370: ...15 14 EZ Match User s Manual Ordered Output Filter...