8-42
EZ Match User’s Manual
Tube/Cap Detection Output 1
Output On
*Important:
There is no “Unknown” condition for Tube Detection. “Unknown” is not a valid
selection for Output On if Detection Mode is set to Tube Detection.
Presence
Based on the mode selected (Tube Detection or Cap Detection), the output will be
asserted if the read cycle results in a
Presence
condition.
Absence
Based on the mode selected (Tube Detection or Cap Detection), the output will be
asserted if the read cycle results in an
Absence
condition.
Unknown
Since there is no “Tube Unknown” condition, the output will be asserted if the read cycle
results in an
Absence
condition and
if the Tube/Cap Detection mode is set to Tube Detection
.
If Tube/Cap Detection mode is set to
Cap Detection
, the
Unknown
condition will output
normally.
Definition:
Output On selects the type of condition in which to output.
Serial Cmd:
<
K860,
mode,
output on
>
Default:
Presence
Options:
0 = Presence
1 = Absence
2 = Unknown*
Содержание EZ Match
Страница 1: ...EZ Match Imager User s Manual P N 83 000044 Rev C...
Страница 12: ...xii EZ Match User s Manual Statement of RoHS Compliance...
Страница 44: ...2 18 EZ Match User s Manual Send Receive Options...
Страница 104: ...4 36 EZ Match User s Manual Postamble...
Страница 122: ...5 18 EZ Match User s Manual Additional Notes about Calibration...
Страница 244: ...8 60 EZ Match User s Manual EZ Trax Output...
Страница 258: ...9 14 EZ Match User s Manual Microscan Symbol Quality Output by ESP...
Страница 270: ...10 12 EZ Match User s Manual New Master Pin...
Страница 370: ...15 14 EZ Match User s Manual Ordered Output Filter...