Workstation 4 and 4 LX Field Service Guide
6-23
Remove and Replace the WS4 and WS4 LX FRUs
Remove and Replace the Touchscreen
Remove and Replace the Touchscreen
This procedure describes how to remove and replace the touchscreen glass and applies
to the Workstation 4 and Workstation 4 LX.
See page 6-4 to remove the Top Cover.
See page 6-8 to remove the RF Shield.
1.
Remove the four screws that hold the MSR spill cover in place. Remove the
reader and bracket assembly and set aside.
2.
Refer to Figure 6-25 and remove the four screws that fasten the LCD Bracket
assembly to the top cover. Remove the LCD Bracket assembly by tilting the
bracket up until it releases.
Figure 6-25: Removing the LCD Bracket
3.
Carefully remove any broken glass from the top cover. Inspect the touchscreen
gasket, clean and reinstall.