page 132
Z589
Round Baler
12.7 F Bus CONTROL SYSTEM
12.7.1 SYSTEM CONNECTION PROBLEMS
PROBLEM
PROBABLE CAUSE
SOLUTION
The control system does not respond
to the ON-OFF button.
The battery supply cable is not
connected to the machine side cable.
Plug the COBO male connector on the
machine side power supply cable in the
COBO female connector on the battery
side power supply cable.
Make sure that the COBO female
connector tab firmly fits the COBO
male connector groove.
The data cable is disconnected from
the terminal.
Plug the data cable connector in the
control terminal female connector.
Tighten to secure.
Reverse polarity.
Switch the cables on the battery
terminals: connect the red cable with
the fuse to the positive (+) and the
black cable to the negative (-).
The battery terminals are tarnished.
Clean the terminals and check the
battery condition.
The minimum voltage level is 12 V.
The fuse is burnt or missing.
Check the fuses in the POWER BOX
module.
Содержание Z589
Страница 126: ...page 123 Z589 Round Baler 11 6 BELT RUNNING Note The arrows show the direction of belt movement...
Страница 130: ...page 127 Z589 Round Baler...
Страница 143: ...page 140 Z589 Round Baler Notes...
Страница 144: ...page 141 Z589 Round Baler...