page 67
Z589
Round Baler
9.7 ELECTRICAL AND ELECTRONIC COMPONENTS
•
Check that the electrical system and the control terminal wiring is not crushed or damaged.
•
Keep all sockets, plugs, cables and sensors clean of mud, earth or collected material.
•
Check the lights and replace all burnt lamps (bulbs) in the lighting system.
See Chapter 10 "F Bus control system" for detailed information about maintenance of the control terminal.
IMPORTANT!
After making the first 200 bales, inspect the machine as instructed above.
9.7.1 SENSORS
The baler features a number of proximity switch sensors which control and monitor the individual work stages of
the machine over the F Bus control system.
Adjust the distance
X
(at approx. 1÷3 mm) between the sensor
S
and its respective reference
R
, as shown in the
example drawing (which is indicative only):
•
With the F Bus control system switched on, operate the sensor mounting nuts on the sensor bracket to move
it closer to or further from the relative reference.
•
The correct distance
X
is set when the sensor LED turns on.
•
Retighten the nuts and verify that the sensor LED is still on after retightening.
IMPORTANT!
Adjust the sensors so that they never touch or collide with their references.
CAUTION!
Adjust all sensors installed on the machine. Follow all safety rules and be extremely careful in
all extremely hazardous areas.
If access to the sensors to be adjusted requires opening or removing a guard (panel), reinstall it completely when
done servicing.