page 79
Z589
Round Baler
9.14.2 OIL TANK
Check the level and refill (if necessary) the automatic lubrication tank oil.
•
Open the left-hand side guard panel.
•
Open the filler cap
T
, refill the tank with oil and
screw the filler cap
T
back in.
•
Close the left-hand side guard panel.
The oil tank capacity is 1.5 litres.
9.14.3 FILTER
Check and periodically inspect the condition of the automatic lubrication filter.
•
Open the left-hand side guard panel.
•
Undo the clip bands
F
and replace the filter with an
identical new one.
•
Retighten the clip bands
F
.
•
Close the left-hand side guard panel.
9.14.4 MANUAL CHAIN LUBRICATION
DANGER! Do not attempt this maintenance procedure with the machine
running:
•
Stop the tractor, remove the ignition key and wait until all machine parts
stop completely.
•
Turn off the control system.
All chains not lubricated by the automatic lubrication system shall be lubricated by hand with an oil and grease
mixture.