-45-
Adjustment
Reset mode
Depending on you application, you can reset a metal detection either
automatically
or
manually.
If no
particular requests have been given by the customer, the metal detectors will be supplied with reset mode
„
automatic
“.
Reset mode automatic:
Time-controlled metal notification is set for automatic ejection of metal-contaminated products. You may set
the delay and duration of the metal notification in the menu “
Operating level 2
Reject parameter
”
Reset mode manual:
With this reset mode, you can only delay the metal signal, e.g. to remove the metal part from the opening.
The machine is restarted by resetting the metal detector at the display or with an external
reset button.
Mechanical delay
This is the set time between the electrical actuation of the ejection mechanism (output at the outputs) and the
ejection diverter meeting the product (ejection). Hence, the mechanical delay due to an ejection system is
eliminated.
The mechanical delay can be set between 0 and 500 milliseconds (ms).
Conveying speed
By means of exact matching to the maximum conveyor speed, external high-frequency influences on the
measurement signal can be eliminated. The set value is dependent on the actual conveyor speed of the unit.
Set the maximum conveyor speed of your conveyor system as the set value.
By adjusting the minimum conveyor speed, low frequency influences on the measurement signal can be
cancelled out. The set value should only be changed if the actual conveyor speed is lower than the preset
value.
Please note:
If the maximum conveyor speed is set lower than the actual product speed, sensitivity losses will occur. If
you do not know the exact speed of your conveyor system, it is preferable to set the maximum conveyor
speed higher than the actual production speed. On no account should it be set lower.
If the minimum conveyor speed is set higher than the actual product speed, sensitivity losses will occur. If
you do not know the exact speed of your conveyor system, it is preferable to set the minimum conveyor
speed lower than the actual production speed. On no account should it be set higher.
Detection
In this menu option you can activate or deactivate the metal detection and ejection procedure of the detector