-27-
Assembly
Detector C-Coil
Drawing number: C 0000 001 A
60
80
38
30
SL
L
H
+ 380
MFZ
BA 1
BA 2
BA 3
SH
LH
SH
X
SH + 60
LB
SH
24
30
30
LB +170
90
1.
Metal-free-zone
MFZ (non moving metal)
= SL + LH
1)
MFZ (moving metal)
= SL + 3,5 x LH
1)
2.
Access line
Ø
9 (Version 2)
3.
Access line
Ø
9 (Version 1)
4.
Mounting foot
: Thread reach: max. = 18 mm
Thread M12
1)
The metal detector has to be positioned centrically within the „metal-free-zone“. The calculated values can
be used for orientation (minimum values can of course be exceeded!) but must be confirmed by us for the
respective project.
LB
(Aperture width)
Aperture
height
LH
Detector
length
SL
Top / Bottom
thickness
SH
Distance between threaded
bore holes
BA 1 BA 2 BA 3
Number of threaded
bore holes for each
detector
A
Measure
X
50 – 150
260
115
130
-
-
4
18
175 – 200
300
115
170
-
-
4
22
225 – 250
350
115
220
-
-
6
26
275 – 300
400
115
230
-
-
6
27
325 – 350
450
115
280
-
-
6
31
375 – 400
500
115
110
330
-
8
36
425 – 450
550
115
190
380
-
10
40
475 – 500
600
115
215
430
-
10
44
550 – 600
650
115
240
480
-
10
49
650 – 700
700
150
265
530
-
10
-
750 – 800
800
150
150
390
630
12
-
850 – 900
900
150
150
440
730
12
-
950 – 1000
1000
150
280
560
830
14
-
LH > 1000
1200
150
340
690
1030
14
-
Dimensions in mm
1
2
3
4
4
Содержание METRON 07 C
Страница 2: ......
Страница 4: ...2 Index...
Страница 18: ...16 Safety...
Страница 34: ...32 Assembly...
Страница 56: ...54 Adjustment...
Страница 70: ...68 Errors and Problems...
Страница 76: ...74 Technology...
Страница 84: ...82 Appendix Example of an EU Declaration of Conformity...