-59-
Errors and Problems
1-008 Notice: „Test Reject: Activation position
sensor, activation time [ms]“
After the test separation has taken place, a message appears on the display. The message informs you about
the measured activation time of the separation diverter.
1-009 Notice: „Test Reject: Reset position
sensor %s, reset time [ms]“
After the test separation has taken place, a message appears on the display. The message informs you about
the measured reset time of the separation diverter.
1-010 Error: „Reject unit: Collecing container full“
The collector bin for ejected material is full.
Empty the collector bin and confirm the notification by pressing the “
OK
” key. The
Cumulative reject
time
is re-set automatically.
Please note:
If the collector bin is not yet full, or its contents have already spilled over, the
Cumulative reject time
setting is incorrect.
1-011 Error: „Pressure monitoring“
There is not enough pressure in order to operate the separation device.
Check the pressurized-air supply.
Note!
This error message appears even it the plant is optionally equipped with a compressed air shutoff valve and
is shut off (also during emergency shutdown).
1-012 Error: „Product jam or check light barrier“
Check the function of the light barrier.
1-013 Error: „Encoder monitoring“
No signal from the rotary encoder. Check the function of the rotary encoder.
1-014 Error: „Contamination level“
When checking the contamination degree of a product flow, a warning is sent when the set criteria are
reached (number of metal occurrences per time interval).