2.
½” male quick-release for door close (max. flow 70 l/min)
3.
½” male quick-release for pick-up reel up (drop floor up)
4.
½” male quick-release for pick-up reel down (drop floor down)
5.
Hydraulic-brake coupling (or two air-brake couplings), if brakes are fitted
6.
12 V / 7-pin lighting socket
7.
12 V, 20 A euro socket (machine loom to control box shown)
See the following image for possible hosing layout. Ensure that the machine operator
is familiar with all tractor connections and fittings.
Possible layout of hydraulic hosing and electric looms
5.8 Connecting the control box
The electronic control box must be located inside the tractor cab in the operator’s field
of vision and within easy reach
(See ‘Electronic control system’)
. It is secured to the
glass using the suction pad on the rear. Ensure that the cable to the machine is not
under tension and not near sharp edges, etc. The control box is to be connected to a
12 V, 20 A power supply, using the supplied euro lead. The control box is not
waterproof, it must be protected from rain.
CAUTION: Do not connect control box to a 24 V power supply
Do not attempt to connect the control box to a power supply greater
than 12 V, as machine component damage will result.