3.0 Setup
Inverting
01 DC Meters
Rotary
SELECT Knob
LCD
Display
METER
Button
Figure 3-5, Meter Button
AUTO:
This selection uses the settings in “04 AGS Setup” to automatically
start and stop the generator. Refer to menu 04 AGS Setup on page 29 to set
the start and stop parameters for the generator.
ON:
The ON selection will start the generator by sending a “start” command
from the ME-AGS-N control module. Once the generator is started it may
be stopped by selecting OFF from the GEN Control menu, this sends a stop
command from the ME-AGS-N control module.
Info:
You can manually start the generator by selecting ON from the
GEN Control menu, and then change the selection to AUTO to auto-
matically stop the generator. When the AUTO setting is selected after
the generator has been manually started it will use the STOP setting
in menu 04A “Set Stop Gen Volts” or menu 04F “Max Gen Run Time”,
whichever occurs
fi
rst. This setting is useful if you want to make sure
the generator starts before you leave, but also want to make sure
the generator doesn’t run too long, thereby wasting fuel.
The start selection uses warm-up time. The stop selection stops im-
mediately it does not use the cool-down time.
Press to
select m eters
press
METER
rotate to
desired
selection :
Status
01 DC Meters
T op line show s inverter/
charger status
Bottom line show s current
m enu heading
T o select the next
M eter m enu
Status
02 AC Meters
Status
03 AGS Meters
Status
04 BMK Meters
Status
01 DC Meters
http://www.wholesalesolar.com/inverter_systems.html