IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
6-7
CPF03
Control Board Connection Error.
Connection error between the control
board and the drive. Can be caused
by a connection error, or the drive
failing to operate properly due to
noise interference.
Connection Error:
1. Turn off the power and check the
connection between the control
board and the drive.
2. If the problem continues, replace
the control board or the entire
drive. Contact Magnetek for
instructions on replacing the
control board.
Noise Interference:
1. Check the various options
available to minimize the effects
of noise.
2. Counteract noise in the control
circuit, main circuit, and ground
wiring.
3. Use only recommended cables
or other shielded line. Ground
the shield on the controller side
or the drive input power side.
4. Ensure that other equipment
such as switches or relays do not
cause noise. Use surge
suppressors if required.
5. Separate all communication
wiring from drive power lines.
Install an EMC noise filter to the
drive power supply input.
X
CPF06
EEPROM Error
EEPROM Memory Data Error.
An
Error in the data saved to EEPROM.
Can be caused by an error in the
EEPROM control circuit, or the power
supply being switched off while
parameters are being saved to the
drive.
Error in the EEPROM Circuit
1. Turn off the power and check the
connection between the control
board and the drive.
2. If the problem continues, replace
the control board or the entire
drive. Contact Magnetek for
instructions on replacing the
control board.
Parameter Save Interruption
1. Reinitialize the drive (A01-03 =
5432).
X
CPF07
CPF08
Terminal Board Connection Error.
There is a fault connection between
the terminal board and the control
board.
1. Turn off the power and reconnect
the terminal board.
1. If the problem continues, replace
the control board or the entire
drive. Contact Magnetek for
instructions on replacing the
control board.
X
CPF20 or
CPF21
Control Circuit Error.
Hardware is
damaged.
1. Cycle power to the drive.
2. If the problem continues, replace
the control board or the entire
drive. Contact Magnetek for
instructions on replacing the
control board.
X
CPF22
Hybrid IC Failure
Hybrid IC Failure.
Hybrid IC failure
on the power board.
1. Cycle power to the drive.
2. If the problem continues, replace
the control board or the entire
drive. Contact Magnetek for
instructions on replacing the
control board.
X
Code
Fault/Alarm Description
Corrective Action
Fa
ult
Alarm
Содержание Impulse G+ series 4
Страница 2: ......
Страница 6: ...IMPULSE G VG Series 4 Instruction Manual February 2017 iv This page intentionally left blank...
Страница 12: ...IMPULSE G VG Series 4 Instruction Manual February 2017 This page intentionally left blank...
Страница 13: ...C h a p t e r 1 Introduction...
Страница 14: ...IMPULSE G VG Series 4 Instruction Manual February 2017 1 2 This page intentionally left blank...
Страница 26: ...IMPULSE G VG Series 4 Instruction Manual February 2017 1 14 This page intentionally left blank...
Страница 27: ...C h a p t e r 2 Installation...
Страница 28: ...IMPULSE G VG Series 4 Instruction Manual February 2017 2 2 This page intentionally left blank...
Страница 40: ...IMPULSE G VG Series 4 Instruction Manual February 2017 2 14 This page intentionally left blank...
Страница 41: ...C h a p t e r 3 Wiring...
Страница 42: ...IMPULSE G VG Series 4 Instruction Manual February 2017 3 2 This page intentionally left blank...
Страница 56: ...IMPULSE G VG Series 4 Instruction Manual February 2017 3 16 Figure 3 10 Grounding Figure 3 11 Motor Grounding...
Страница 63: ...IMPULSE G VG Series 4 Instruction Manual February 2017 3 23 Figure 3 16 Safe Torque Off Block Diagram...
Страница 66: ...IMPULSE G VG Series 4 Instruction Manual February 2017 3 26 This page intentionally left blank...
Страница 67: ...C h a p t e r 4 Getting Started...
Страница 68: ...IMPULSE G VG Series 4 Instruction Manual February 2017 4 2 This page intentionally left blank...
Страница 87: ...C h a p t e r 5 Programming Advanced Features...
Страница 88: ...IMPULSE G VG Series 4 Instruction Manual February 2017 5 2 This page intentionally left blank...
Страница 223: ...C h a p t e r 6 Troubleshooting...
Страница 224: ...IMPULSE G VG Series 4 Instruction Manual February 2017 6 2 This page intentionally left blank...
Страница 255: ...a p p e n d i x A IMPULSE G VG Series 4 Parameter Listing...
Страница 256: ...IMPULSE G VG Series 4 Instruction Manual February 2017 A 2 This page intentionally left blank...