IMPULSE®•G+ & VG+ Series 4 Instruction Manual – February 2017
5-42
3.
Configure the E-Lift Parameters:
The parameters listed in Table 5-33 are used to configure the E-Lift function.
Table 5-33: E-Lift Parameters
4. Conduct a Preliminary E-Lift Test:
After all parameters have been configured in steps 2 and 3, the E-Lift function must be tested to
ensure it can raise and lower a load properly. Conduct the following steps to verify the E-Lift
function:
a. Attach a test load to the hoist (rated capacity is recommended).
b. Raise the load approximately one foot above the floor.
c. Turn on the MFDI associated with E-Lift enable (H01-01 ~ H01-08 = 44H).
d. Inspect the display on the digital operator. The flashing title should alternate between
“Emergency Lift” and the present menu title, which confirms that the E-Lift function is active.
e. Perform a series of raise and lower commands and observe the test load.
f.
If steps 4.a through 4.e were successful, turn off the E-Lift MFDI and return the hoist to
normal operations.
Parameter Display
Function
Range
Default
C08-35
Emergency Lift
Determines whether the E-Lift
MFDI function is enabled.
0, 2
2
0
Disabled
2
Enabled by MFDI
C08-36
ELift Max Speed
Maximum frequency reference
when E-Lift is active.
0–150 Hz
30
C08-37
ELift Max Time
Maximum time that E-Lift can be
active.
0–6000 s
600
D A N G E R
If any undesired motions occur while E-Lift is active, immediately remove any RUN
commands, turn off the E-Lift MFDI, and contact Magnetek.
Содержание Impulse G+ series 4
Страница 2: ......
Страница 6: ...IMPULSE G VG Series 4 Instruction Manual February 2017 iv This page intentionally left blank...
Страница 12: ...IMPULSE G VG Series 4 Instruction Manual February 2017 This page intentionally left blank...
Страница 13: ...C h a p t e r 1 Introduction...
Страница 14: ...IMPULSE G VG Series 4 Instruction Manual February 2017 1 2 This page intentionally left blank...
Страница 26: ...IMPULSE G VG Series 4 Instruction Manual February 2017 1 14 This page intentionally left blank...
Страница 27: ...C h a p t e r 2 Installation...
Страница 28: ...IMPULSE G VG Series 4 Instruction Manual February 2017 2 2 This page intentionally left blank...
Страница 40: ...IMPULSE G VG Series 4 Instruction Manual February 2017 2 14 This page intentionally left blank...
Страница 41: ...C h a p t e r 3 Wiring...
Страница 42: ...IMPULSE G VG Series 4 Instruction Manual February 2017 3 2 This page intentionally left blank...
Страница 56: ...IMPULSE G VG Series 4 Instruction Manual February 2017 3 16 Figure 3 10 Grounding Figure 3 11 Motor Grounding...
Страница 63: ...IMPULSE G VG Series 4 Instruction Manual February 2017 3 23 Figure 3 16 Safe Torque Off Block Diagram...
Страница 66: ...IMPULSE G VG Series 4 Instruction Manual February 2017 3 26 This page intentionally left blank...
Страница 67: ...C h a p t e r 4 Getting Started...
Страница 68: ...IMPULSE G VG Series 4 Instruction Manual February 2017 4 2 This page intentionally left blank...
Страница 87: ...C h a p t e r 5 Programming Advanced Features...
Страница 88: ...IMPULSE G VG Series 4 Instruction Manual February 2017 5 2 This page intentionally left blank...
Страница 223: ...C h a p t e r 6 Troubleshooting...
Страница 224: ...IMPULSE G VG Series 4 Instruction Manual February 2017 6 2 This page intentionally left blank...
Страница 255: ...a p p e n d i x A IMPULSE G VG Series 4 Parameter Listing...
Страница 256: ...IMPULSE G VG Series 4 Instruction Manual February 2017 A 2 This page intentionally left blank...