53
MagCore®
Plus II
━ Jog Test
Sensors
M-axis: Down sensor
X-axis: Home sensor
V-axis: Home sensor
Y-axis: Home sensor
Door Sensor
M-axis: Up sensor
Jog test helps to identify issues with axis movements, encoder condition and function
and check the motors.
The two values, the Encoder and the Pulse, should be the same or +-10. If they are
not, clean the encoder disc. Run the test again to confirm the values match.
Maintenance-Motor Jog
If you press [JOG] too much,
it will generate an error and encoder and pluse > ± 10 te may be a problem!
07/13/2020 09:25:32
X Axis Motor
Encoder
Pluse
Speed
25128
25130
12000
0
0
30000
-1
0
21000
Encoder
Pluse
Speed
Encoder
Pluse
Speed
Y Axis Motor
V Axis Motor
LS+
Home
LS-
LS+
Home
LS-
LS+
Home
LS-
Back
Jog +
Jog -
Jog +
Jog -
Jog +
Jog -
Middle SP.
5000
Middle SP.
10000
Middle SP.
8000
Low SP.
400
Low SP.
500
Low SP.
1000
Adminstrator
Back
Load Speed Default
Teach Position
Motor JOG Test
IO Check
Test Run
Reset
07/13/2020 09:25:32