262391
44
Revision A
1.
Raise the header fully.
2.
Shut down the engine, and remove the key from the ignition.
ϭϬϰϯϲϬϳ
A
Figure 3.31: Cylinder Lock-Out Valve
–
Closed Position
3.
Close the rotary disc header
’
s auxiliary lift cylinder lock-out
valve (A) on each lift cylinder by turning the handle to the
horizontal position (90° to the hose). Repeat this step on
the opposite side.
ϭϬϰϯϲϲϰ
A
B
C
Figure 3.32: Float Spring
–
Right Side
4.
Loosen retaining bolt (A) and rotate cover plate (B) away
from float spring bolt (C). Repeat this step on the
opposite side.
5.
Fully loosen float spring bolt (C). Repeat on opposite side.
ϭϬϰϯϲϲϱ
A
B
Figure 3.33: Adjuster Bolt
6.
Turn adjuster bolt (A) to achieve the recommended
measurement (B) for the conditioner type. Refer to
Table
for measurements.
NOTE:
Float settings indicated in the table are starting points.
Float force should be checked with header float and cutting
angle set as planned for use in the field.
•
Turn bolt (A) clockwise (towards the spring) to
increase float.
•
Turn bolt (A) counterclockwise (away from the spring)
to decrease float.
Repeat this step on the opposite side.