18
7xETBLD USERS MANUAL EM-7353-0003C
2.6.7 REMOTE MRD TOOL
‘CF Data to MRD’ file conversion can be executed also via Ethernet.
Data stored by the 7xET can be converted into the format compatible with the MSR128-V2 or MSR128-V3 (MRD
File) so that the data can be displayed on the MSR128 software.
This procedure is not required for the MSR128-V4.
Figure 18: FTP7xET.
Specify the IP address of the 7xET where the data is stored.
Specify the date and time to start and stop reading. (Seconds cannot be specified.)
Click [OK] starts file transfer. When the transfer is complete, ‘Remote MRD Tool’ window appears on the screen.
Figure 19: Remote MRD Tool.
Specify in ‘Output File’ field the directory path where the converted MRD file is to be saved.
Specify in ‘Output File Number’ the number to be added at the end of the new file name (‘N’ of the file name based
on the date ‘YYMMDD-N.’) N = 1 through 9999.
Choose the target MSR128 software version.
Click [OK].
APPENDIX-A ETHERNET CABLE
Different cable types are used depending on how the 7xET and the PC installed with the 7xETBLD are connected via
Ethernet.
CONNECTION VIA ETHERNET HUB/SWITCH
Use a ‘Straight Through’ cable between each device and the hub. (Figure A-1)
DIRECT CONNECTION
Use a ‘Crossover’ cable between the PC and the 7xET. (Figure A-2)
Figure A-1.
Figure A-2.
If the 7xETBLD shows “Connect Error” saying Ethernet connection is unavailable, confirm the connection on the
Windows MS-DOS.
Confirm Connect Error type