10
73ET/74ET/75ET USERS MANUAL EM-7353-0003B Rev.5
• Ambient temperature: 0 to 50
°
C (except for 73ET for 0 to 45
°
C)
Ambient humidity: 30 to 85% RH
Ambient temperature refers to both the temperatures behind the panel and over the panel.
• We recommend to mount the 7xET on a vertical panel. With a slanted panel, the 7xET must not incline more than 30
degrees from the vertical. If the 7xET is to be installed in greater angle, use a forced-air cooling system to maintain
the ambient temperature lower than 50
°
C.
Figure 1.4.1b: Mounting angle.
• Horizontal (rotated) installation is not allowed.
1.4.2
PANEL CUTOUT (unit: mm)
■
73ET
■
74ET
■
75ET
30°
30°
30° or less
from vertical
156
Panel thickness: 1.6 – 10.0 mm
123.5
+1
0
+1
0
4–R3 max.
Panel thickness: 1.6 – 10.0 mm
204.5
+1
0
159.5
+1
0
4–R3 max.
Panel thickness: 1.6 – 10.0 mm
227.5
+1 0
4–R3 max.
301.5
+1
0
Содержание 75ET
Страница 24: ...20 7xETBLD USERS MANUAL EM 7353 0003C...