Appendix D
© 2018 Avco Corporation. All Rights Reserved
Page 506
November 2018
TEO-540-C1A Engine Maintenance Manual
Fault ID
392
Fault Group
50
Fault Name
[FAULT: control priority message
out-of-sync]
Fault
Description
Control Priority message out-of-sync-
fault
Fault Lamp
NTO
Root Cause
This fault indicates the PWM and CAN 1 control state disagree for a period of time
possibly due to an unexpected response from standby channel (unexpected heartbeat) or
CAN 1 failure
Fault ID
393
Fault Group
50
Fault Name
[FAULT: control priority PWM]
Fault
Description
Control Priority PWM heartbeat duty
cycle fault
Fault Lamp
NTO
Root Cause
This fault indicates remote PWM heartbeat has an invalid frequency or duty cycle possibly
due to an unexpected response from standby channel
Fault ID
394
Fault Group
50
Fault Name
[FAULT: remote PWM heartbeat
duty cycle]
Fault
Description
Remote PWM heartbeat duty cycle
fault
Fault Lamp
NTO
Root Cause
This fault indicates remote PWM heartbeat has an invalid duty cycle possibly due to an
unexpected response from standby channel
Fault ID
395
Fault Group
50
Fault Name
[FAULT: control priority PWM
frequency invalid]
Fault
Description
Control Priority PWM invalid
frequency
Fault Lamp
NTO
Root Cause
This fault indicates remote PWM heartbeat has an invalid frequency possibly due to an
unexpected response from standby channel
Troubleshooting Steps for Faults 392 thru 395
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault active? If no, go to step 2. If yes, replace the ECU.
2.
Clear Service faults using the FST by following the steps outlined in the “Access the Field Service
Tool” section in Appendix C or the latest revision of
SSP-118.
Fault ID
396
Fault Group
50
Fault Name
-Reserved-
Fault
Description
Fault Lamp
NTO
Root Cause
Troubleshooting Steps
Fault ID
397
Fault Group
50
Fault Name
-Reserved-
Fault
Description
Fault Lamp
NTO
Root Cause
Troubleshooting Steps