Engine Assembly Checklist for TEO-540-C1A Engines (Cont.)
Item
Comments
Done
Measure the camshaft end play in the left crankcase
half per the “Camshaft Installation” procedure in
the “Camshaft Assembly and Installation” section
of Chapter 72-20.
*Measurement:
Install the camshaft in the right crankcase half per
the “Camshaft Installation” procedure in the
“Camshaft Assembly and Installation” section of
Chapter 72-20.
Measure the camshaft end play in the right
crankcase half per the “Camshaft Installation”
procedure in the “Camshaft Assembly and
Installation” section of Chapter 72-20.
*Measurement:
Measure the crankshaft bearing journals. Refer to
the “Crankshaft Bearing Surface Inspection”
section in Chapter 72-20.
*Measurement:
Complete the “Crankshaft Installation” procedure
in Chapter 72-20.
Measure the thrust face clearances between the
crankshaft and crankcase per the “Crankshaft
Installation” procedure in Chapter 72-20.
*Measurement:
Measure the slinger clearance per the “Crankshaft
Installation” procedure in Chapter 72-20.
*Measurement:
Measure the crankshaft end play clearance per the
“Crankshaft Installation” procedure in Chapter 72-
20.
*Measurement:
Assemble the crankcase halves per the “Crankcase
Assembly” procedure and follow the torque
sequence in Chapter 72-20.
Complete the “Crankshaft End Play Clearance
Check” in Chapter 72-20 (after the crankcase is
assembled).
Complete the “Propeller Oil Control Leak Test” in
Chapter 72-20
Install the propeller governor per the airframe
manufacturer’s instructions
Complete the “Crankshaft Oil Seal Installation”
procedure in Chapter 72-20.
Complete the “Crankshaft Trigger Gear Assembly
and Crankshaft Idler Gear Installation” procedure in
Chapter 72-20.
*
Measurements must be within tolerances specified in the latest revision of the
Service Table of