TEO-540-C1A Engine Maintenance Manual
Fault ID
14
Fault Group
2
Fault Name
[FAULT: INSTRUCTION TLB]
Fault
Description
TLB instruction access exception
Fault Lamp
NTO
Root Cause
This fault indicates an invalid entry from the instruction translation lookup into the TLB
(Translation Lookaside Buffer) caused by a possible hardware issue (processor, memory
corruption)
Troubleshooting Steps
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault active? If no, go to step 3. If yes, go to step 2.
2.
Contact Lycoming Personnel to have the ECU reprogrammed. Is fault active or reprogram
unsuccessful? If no, go to step 3. If yes, replace the ECU.
3.
Clear Service faults using the FST by following the steps outlined in the “Access the Field Service
Tool” section in Appendix C or the latest revision of
SSP-118.
4.
If fault repeats, replace the ECU.
Fault ID
15
Fault Group
2
Fault Name
[FAULT: MASTER CFG ERROR]
Fault
Description
Master configuration corrupt
Fault Lamp
NTO
Root Cause
This fault indicates a failed checksum for Master configuration block.
Troubleshooting Steps
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault active? If no, go to step 3. If yes, go to step 2.
2.
Contact Lycoming Personnel to have the ECU reprogrammed. Is fault active or reprogram
unsuccessful? If no, go to step 3. If yes, replace the ECU.
3.
Clear Service faults using the FST by following the steps outlined in the “Access the Field Service
Tool” section in Appendix C or the latest revision of
SSP-118.
4.
If fault repeats, replace the ECU.
Fault ID
16
Fault Group
3
Fault Name
[FAULT: MACHINE CHECK]
Fault
Description
Machine Check Exception
Fault Lamp
NTO
Root Cause
This fault indicates a machine check exception Interrupt Vector Register 1 (IVOR1) from
processor possibly due to a hardware issue.
Troubleshooting Steps
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault active? If no, go to step 3. If yes, go to step 2.
2.
Contact Lycoming Personnel to have the ECU reprogrammed. Is fault active or reprogram
unsuccessful? If no, go to step 3. If yes, replace the ECU.
3.
Clear Service faults using the FST by following the steps outlined in the “Access the Field Service
Tool” section in Appendix C or the latest revision of
SSP-118.
4.
If fault repeats, replace the ECU.